SENSORAY | p. 503.684.8005 | email:info@SENSORAY.com | www.SENSORAY.com
7313 SW Tech Center Drive | Portland, OR 97203
HD IP Camera with H.264 Compression
Hardware Manual
Model 3011 | Ver. 1.0.1 | February 2015
Vedere la pagina 0
1 2 3 4 5 6 ... 28 29

Sommario

Pagina 1 - Hardware Manual

SENSORAY | p. 503.684.8005 | email:[email protected] | www.SENSORAY.com7313 SW Tech Center Drive | Portland, OR 97203HD IP Camera with H.264 Compressi

Pagina 2 - Table of Contents

RTSP streamsLive View / RTSP Streams page provides a list of rtsp:// URLs which can be viewed using VLC or another RTSP-compatible player. The player

Pagina 3 - Limited warranty

RTSP streams use TCP port 8554 and UDP ports 6970-6999.11

Pagina 4 - Introduction

Stream ControlStream control window allows individual network configuration and control of each of the two streams.The “Current” section displays the

Pagina 5 - Connectors

Startup: if set to On, the stream will start automatically when the 3011 is powered up.13

Pagina 6

Stream ConfigurationStream configuration window allows configuring individual stream parameters which may differ between streams A and B.Format: allow

Pagina 7 - Web page interface

Aspect ratio setting may help achieve better viewing experience with some combinationsof video sources and stream players. Transform field allows sele

Pagina 8 - Live stream view

Stream Configuration - VideoStream Config – Video window allows configuration of video parameters common to both streams A and B. Brightness, saturati

Pagina 9

Stream Configuration - SnapshotThis page allows taking JPEG snapshots at up to full 13 Mp resolution.17

Pagina 10 - RTSP streams

Clock ConfigurationThe Clock Configuration page allows setting the 3011 internal clock either manually (using a 24-hour format), or to the host's

Pagina 11

Network ManagementEach 3011 is shipped with a default IP address 192.168.30.11 and a netmask 255.255.0.0. Those settings can be modified using a Web p

Pagina 12 - Stream Control

Table of ContentsLIMITED WARRANTY...3INTRODUCTION.

Pagina 13

Depending on the network restrictions one or two steps may be necessary to set a new IP address. If the network used to configure the unit can not acc

Pagina 14 - Stream Configuration

Once the 3011 receives a network packet addressed to it, the temporary IP address will be in effect. To send a packet either ping the board or connect

Pagina 15

User managementUser Management window allows access to the device to be limited to certain users with an associated permission level. The permissions

Pagina 16 - Stream Configuration - Video

• Admin (full access).To create a new user account, click the Create new user link.To delete a user account, check the checkbox below the red X in the

Pagina 17

To create a new user, enter the user name and password, select the desired permission level and then click Create User.Both user name and password are

Pagina 18 - Clock Configuration

Firmware updateThe Firmware Update window displays the versions of the device's firmware components and the serial number. To update the firmwar

Pagina 19 - Network Management

Firmware resetDuring the firmware update the new firmware image is stored into a new location of the internal flash memory storage, while the original

Pagina 20

Traversing routersThe following ports need to be accessible:• for browser preview: TCP port 1935;• for RTSP streams: TCP port 8554, UDP ports 6970-699

Pagina 21

SpecificationsImage sensor Progressive scan, CMOS, 4192 x 3104 (Sony FCB-MA130) Focus range 100 mm to infinity Compression H.264 High Profile at Leve

Pagina 22 - User management

Revision historyVersion Notes1.0.1, February 2015 “Firmware reset” and “Traversing routers” sections added.1.0.0, December 2014 Initial release.29

Pagina 23

Limited warrantySensoray Company, Incorporated (Sensoray) warrants the hardware to be free from defects in material and workmanship and perform to app

Pagina 24

IntroductionModel 3011 is a miniature HD IP camera that fits in a 2.25 x 2.00 x 1.20 inch enclosure (including the lens). The camera is capable of pro

Pagina 25 - Firmware update

ConnectorsFig.1. Model 3011 connectors.Left to right:• Ethernet connector;• GPIO and power terminal block.Below:• status LED;• configuration button.Mo

Pagina 26 - Firmware reset

Fig.2. Optoisolated GPIO.GPIO requires power (pins GPIO-VCC and GND) in the range of 3 to 5 VDC. The input pin (GPI-A) is connected to an anode of an

Pagina 27 - Traversing routers

Web page interfaceMain menuMain Menu is the default screen displayed when the browser connects to the 3011. The default IP address as shipped is 192.1

Pagina 28 - Specifications

Live stream viewLive stream view windows display the live view of one of the two streams available from the 3011. To access the window click on one of

Pagina 29 - Revision history

Live View is not supported when the stream is configured as MPEG4.The web player is using Flash RTMP protocol on TCP port 1935.9

Commenti su questo manuale