0 if success, negative if error.
MID2250_API int SN_StopMD(
int board
);
Stops motion detection.
Parameters
board
Board number in system.
Returns
0 if success, negative if error.
MID2250_API int SN_DisplayMDRegions(
BOOL bOnOff,
int board
);
Displays motion detection regions on displayed image (if rendering the video to screen). Requires
Windows XP or DirectX 9 (Windows 2000).
Parameters
bOnOff
display on or off
board
Board number in system.
Returns
0 if success, negative if error.
MID2250_API int SN_GetMDData(
int *region,
unsigned char *buf,
int bufsize,
int board
);
31